Measurement Solutions
Nexus - R200
Conductance sensor for process monitoring.
-
Conductance measurement
-
Safe Non-radioactive design
-
Range: 0.1 microSiemens - 1 Siemens
-
PTP Timestamp
-
Non-invasive probe - ring electrodes
-
Non-invasive probe - rod electrode
-
Temporal resolution: up to 100000 samples/s/ch.
-
Measurement resolution 16 bits
-
Trigger in/out
-
Power: 15 VDC - 24 VDC
-
Output: 4-20 mA / 0-10 VDC / RS-485 / RS-232 / Wi-Fi
-
Stainless steel / copper electrodes
-
IP65 protection level
-
Ex Intrinsically Safe
Raptor RCT Sensor
Capacitive and Conducatante sensor for process monitoring.
-
Capacitance and Conductance measurement
-
Non-invasive sensor - ring electrodes
-
Non-invasive probe - rod electrode
-
Range C: 0.1 pF - 250 nF
-
Range R: 0.1 microSiemens - 1 Siemens
-
PTP Timestamp
-
Temporal resolution: 2000 samples/s - 13000 samples/s.
-
Measurement resolution 12 bits, 14 bits, 16 bits, 28 bits
-
Power: 15 VDC - 24 VDC
-
Output: 4-20 mA / 0-10 VDC / RS-485 / LAN / Wi-Fi
-
Stainless steel / copper electrodes
-
IP65 protection level
Rod Sensor - ROD-F100-I-Ex
Capacitive sensor for process monitoring.
-
Capacitance measurement
-
Range: 0.1 pF - 200 nF
-
Safe Non-radioactive design
-
Intrusive sensor - Flange
-
Layout: ROD-Sensor
-
Temporal resolution: 2000 samples/s - 10000 samples/s.
-
Measurement resolution 12 bits, 14 bits, 16 bits, 28 bits
-
PTP: data time-stamp
-
Power: 15 VDC - 24 VDC
-
Output: 4-20 mA / 0-10 VDC / RS-485 / RS-232 / Wi-Fi
-
Stainless steel / copper electrodes
-
IP65 protection level
-
Ex ia IIB T4 Ga
Cap Sensor - C100-F-Ex
Capacitive sensor for process monitoring.
-
Capacitive measurement
-
Safe Non-radioactive design
-
Non-invasive sensor - Flange
-
Layout: Concave
-
Temporal resolution: 2000 samples/s - 10000 samples/s.
-
Measurement resolution 12 bits, 14 bits, 16 bits, 28 bits
-
PTP: data time-stamp
-
Power: 15 VDC - 24 VDC
-
Output: 4-20 mA / 0-10 VDC / RS-485 / RS-232 / Wi-Fi
-
Stainless steel / copper electrodes
-
IP65 protection level
-
Ex ia IIB T4 Ga
Clamp-on Sensor - CAP-C100
Capacitive sensor for flow monitoring.
-
Capacitive measurement
-
Safe Non-radioactive design
-
Non-invasive sensor - Flange
-
Layout: Helix
-
Temporal resolution: 2000 samples/s - 10000 samples/s.
-
Measurement resolution 12 bits, 14 bits, 16 bits, 28 bits
-
PTP: data time-stamp
-
Power: 15 VDC - 24 VDC
-
Output: 4-20 mA / 0-10 VDC / RS-485 / RS-232 / Wi-Fi
-
Stainless steel / copper electrodes
-
IP65 protection level
-
Ex ia IIB T4 Ga